High pressure expander
Inflatable Due to their geometry and expandability, seals can be used for a wide range of applications. In addition to the sealing function, the area of application also includes clamping, lifting and pressure functions.
In addition to standardized profile geometries, customer-specific solutions can also be implemented!
Versions without eCORE are also available!
31410 V
FDA § 177.2600 - conformity, BfR XV - conformity
Fire protection on request / steam sterilization +135 ° C
silicone Gray DIN ISO 3302-1 E2 L2 -50 ° C to 200 ° C
Dimensions
Stroke recommendation
Stroke max.
operating pressure
Installation radius recommendation
A: 14 mm
2.5 mm
B: 10 mm
3.5 mm
4 bar
expansion axial 70 mm
expansion radially outside 40 mm
expansion radially inside 70 mm
31612 V
FDA § 177.2600 - conformity, BfR XV - conformity
Fire protection on request / steam sterilization +135 ° C
silicone red-brown DIN ISO 3302-1 E2 L2 -50 ° C to 200 ° C
Dimensions
Stroke recommendation
Stroke max.
operating pressure
Installation radius recommendation
A: 16 mm
3 mm
B: 12 mm
4 mm
4 bar
expansion axial 95 mm
expansion radially outside 45 mm
expansion radially inside 45 mm
32521 V
FDA § 177.2600 - conformity, BfR XV - conformity
Fire protection on request / steam sterilization +135 ° C
silicone red-brown DIN ISO 3302-1 E2 L2 -50 ° C to 200 ° C
Dimensions
Stroke recommendation
Stroke max.
operating pressure
Installation radius recommendation
A: 25 mm
4th mm
B: 21 mm
5 mm
6 bar
expansion axial 125 mm
expansion radially outside 80 mm
expansion radially inside 85 mm
32619 V
FDA § 177.2600 - conformity, BfR XV - conformity
Fire protection on request / steam sterilization +135 ° C
silicone red-brown DIN ISO 3302-1 E2 L2 -50 ° C to 200 ° C
Dimensions
Stroke recommendation
Stroke max.
operating pressure
Installation radius recommendation
A: 26 mm
4th mm
B: 19 mm
5 mm
6 bar
expansion axial 125 mm
expansion radially outside 80 mm
expansion radially inside 85 mm
32622 V
FDA § 177.2600 - conformity, BfR XV - conformity
Fire protection on request / steam sterilization +135 ° C
silicone red-brown DIN ISO 3302-1 E2 L2 -50 ° C to 200 ° C
Dimensions
Stroke recommendation
Stroke max.
operating pressure
Installation radius recommendation
A: 26 mm
5 mm
B: 22 mm
6 mm
6 bar
expansion axial 130 mm
expansion radially outside 90 mm
expansion radially inside 90 mm
33532 V
FDA § 177.2600 - conformity, BfR XV - conformity
Fire protection on request / steam sterilization +135 ° C
silicone red-brown or white DIN ISO 3302-1 E2 L2 -50 ° C to 200 ° C
Dimensions
Stroke recommendation
Stroke max.
operating pressure
Installation radius recommendation
A: 35 mm
9 mm
B: 32 mm
11th mm
8.5 bar
expansion axial 175 mm
expansion radially outside 130 mm
expansion radially inside 125 mm
31410 F
FKM black DIN ISO 3302-1 E2 L2 -50 ° C to 200 ° C
Dimensions
Stroke recommendation
Stroke max.
operating pressure
Installation radius recommendation
A: 14 mm
2.5 mm
B: 10 mm
3.5 mm
4 bar
expansion axial 70 mm
expansion radially outside 40 mm
expansion radially inside 70 mm
32521 F
FKM black DIN ISO 3302-1 E2 L2 -50 ° C to 200 ° C
Dimensions
Stroke recommendation
Stroke max.
operating pressure
Installation radius recommendation
A: 25 mm
4th mm
B: 21 mm
5 mm
6 bar
expansion axial 125 mm
expansion radially outside 80 mm
expansion radially inside 85 mm
32619 F
FKM black DIN ISO 3302-1 E2 L2 -50 ° C to 200 ° C
Dimensions
Stroke recommendation
Stroke max.
operating pressure
Installation radius recommendation
A: 26 mm
4th mm
B: 19 mm
5 mm
6 bar
expansion axial 125 mm
expansion radially outside 80 mm
expansion radially inside 85 mm
32622 F
FKM black DIN ISO 3302-1 E2 L2 -20 ° C to 200 ° C
Dimensions
Stroke recommendation
Stroke max.
operating pressure
Installation radius recommendation
A: 26 mm
5 mm
B: 22 mm
6 mm
6 bar
expansion axial 130 mm
expansion radially outside 90 mm
expansion radially inside 90 mm
33532 F
FKM black DIN ISO 3302-1 E2 L2 -50 ° C to 200 ° C
Dimensions
Stroke recommendation
Stroke max.
operating pressure
Installation radius recommendation
A: 35 mm
9 mm
B: 32 mm
11th mm
8.5 bar
expansion axial 175 mm
expansion radially outside 130 mm
expansion radially inside 125 mm