top of page
eCoreSeal.jpg

High pressure expander

Inflatable  Due to their geometry and expandability, seals can be used for a wide range of applications. In addition to the sealing function, the area of application also includes clamping, lifting and pressure functions.

In addition to standardized profile geometries, customer-specific solutions can also be implemented!

Versions without eCORE  are also available!

33532  E.

EPDM gray  or black                    DIN ISO 3302-1 E2 L2                                  -20 ° C to 100 ° C

Dimensions

Stroke recommendation

A: 35     mm

 9  mm

Stroke max.

operating pressure

Installation radius recommendation

11th  mm

8 bar

expansion  axial           175 mm

B: 32      mm

expansion  radially outside  130 mm

expansion  radially inside     125 mm

Ausdehner_transp_max.png

31410  V

FDA § 177.2600 - conformity, BfR XV - conformity

Fire protection on request / steam sterilization +135 ° C

silicone Gray                                DIN ISO 3302-1 E2 L2                                  -50 ° C to 200 ° C

Dimensions

Stroke recommendation

Stroke max.

operating pressure

Installation radius recommendation

A: 14   mm

 2.5  mm

B: 10   mm

3.5 mm

4 bar

expansion  axial           70 mm

expansion  radially outside   40 mm

expansion  radially inside     70 mm

31612 V

FDA § 177.2600 - conformity, BfR XV - conformity

Fire protection on request / steam sterilization +135 ° C

silicone red-brown                            DIN ISO 3302-1 E2 L2                                  -50 ° C to 200 ° C

Dimensions

Stroke recommendation

Stroke max.

operating pressure

Installation radius recommendation

A: 16   mm

 3  mm

B: 12   mm

4 mm

4 bar

expansion  axial           95 mm

expansion  radially outside   45  mm

expansion  radially inside     45  mm

32521 V

FDA § 177.2600 - conformity, BfR XV - conformity

Fire protection on request / steam sterilization +135 ° C

silicone red-brown                            DIN ISO 3302-1 E2 L2                                  -50 ° C to 200 ° C

Dimensions

Stroke recommendation

Stroke max.

operating pressure

Installation radius recommendation

A: 25   mm

 4th  mm

B: 21   mm

5 mm

6 bar

expansion  axial           125  mm

expansion  radially outside   80  mm

expansion  radially inside     85  mm

32619 V

FDA § 177.2600 - conformity, BfR XV - conformity

Fire protection on request / steam sterilization +135 ° C

silicone red-brown                            DIN ISO 3302-1 E2 L2                                  -50 ° C to 200 ° C

Dimensions

Stroke recommendation

Stroke max.

operating pressure

Installation radius recommendation

A: 26   mm

 4th  mm

B: 19   mm

5 mm

6 bar

expansion  axial           125  mm

expansion  radially outside   80  mm

expansion  radially inside     85  mm

32622  V

FDA § 177.2600 - conformity, BfR XV - conformity

Fire protection on request / steam sterilization +135 ° C

silicone red-brown                            DIN ISO 3302-1 E2 L2                                  -50 ° C to 200 ° C

Dimensions

Stroke recommendation

Stroke max.

operating pressure

Installation radius recommendation

A: 26   mm

 5  mm

B: 22   mm

6 mm

6 bar

expansion  axial           130  mm

expansion  radially outside   90  mm

expansion  radially inside     90  mm

33532 V

FDA § 177.2600 - conformity, BfR XV - conformity

Fire protection on request / steam sterilization +135 ° C

silicone red-brown or white                   DIN ISO 3302-1 E2 L2                                  -50 ° C to 200 ° C

Dimensions

Stroke recommendation

Stroke max.

operating pressure

Installation radius recommendation

A: 35   mm

 9  mm

B: 32   mm

11th  mm

8.5 bar

expansion  axial           175  mm

expansion  radially outside   130  mm

expansion  radially inside     125  mm

31410 F

FKM black                                DIN ISO 3302-1 E2 L2                                   -50 ° C to 200 ° C

Dimensions

Stroke recommendation

Stroke max.

operating pressure

Installation radius recommendation

A: 14   mm

 2.5  mm

B: 10   mm

3.5 mm

4 bar

expansion  axial           70 mm

expansion  radially outside   40 mm

expansion  radially inside     70 mm

32521 F

FKM black                            DIN ISO 3302-1 E2 L2                                       -50 ° C to 200 ° C

Dimensions

Stroke recommendation

Stroke max.

operating pressure

Installation radius recommendation

A: 25   mm

 4th  mm

B: 21   mm

5 mm

6 bar

expansion  axial           125  mm

expansion  radially outside   80  mm

expansion  radially inside     85  mm

32619 F

FKM black                            DIN ISO 3302-1 E2 L2                                        -50 ° C to 200 ° C

Dimensions

Stroke recommendation

Stroke max.

operating pressure

Installation radius recommendation

A: 26   mm

 4th  mm

B: 19   mm

5 mm

6 bar

expansion  axial           125  mm

expansion  radially outside   80  mm

expansion  radially inside     85  mm

32622 F

FKM black                               DIN ISO 3302-1 E2 L2                                  -20 ° C to 200 ° C

Dimensions

Stroke recommendation

Stroke max.

operating pressure

Installation radius recommendation

A: 26   mm

 5  mm

B: 22   mm

6 mm

6 bar

expansion  axial           130  mm

expansion  radially outside   90  mm

expansion  radially inside     90  mm

33532 F

FKM black                           DIN ISO 3302-1 E2 L2                                  -50 ° C to 200 ° C

Dimensions

Stroke recommendation

Stroke max.

operating pressure

Installation radius recommendation

A: 35   mm

 9  mm

B: 32   mm

11th  mm

8.5 bar

expansion  axial           175  mm

expansion  radially outside   130  mm

expansion  radially inside     125  mm